Products

Product Overview

Non-oriented electrical steel

Standard product size

Nominal thickness (mm) Nominal width (mm) Inner diameter (mm)
0.20 0.35 0.50 0.65 800~1250 508

Size and shape tolerance

Nominal thickness (mm) Nominal width (mm) Allowable thickness deviation (mm) Longitudinal thickness difference (mm) Transverse thickness difference (mm) Allowable width deviation (mm) Unevenness (%) 2m camber (mm)
800~1000 0.20 ±0.02 ≤0.02 ≤0.02 +1.5 0 ≤2 ≤1.0
0.35 ±0.03 ≤0.02 ≤0.02
0.50 ±0.04 ≤0.03 ≤0.02
0.65 ±0.04 ≤0.04 ≤0.03
>1000 0.20 ±0.02 ≤0.02 ≤0.02 +1.5 0
0.35 ±0.03 ≤0.02 ≤0.02
0.50 ±0.03 ≤0.03 ≤0.02
0.65 ±0.04 ≤0.04 ≤0.03

Grain-oriented electrical steel

Standard product size

Nominal thickness (mm) Nominal width (mm) Inner diameter (mm)
0.23 0.27 0.30 0.35 700~1200 508

Size and shape tolerance

Nominal thickness (mm) Nominal width (mm) Allowable thickness deviation (mm) Longitudinal thickness difference (mm) Transverse thickness difference (mm) Allowable width deviation (mm) Unevenness (%) 2m camber (mm)
700~1200 0.23 ±0.02 ≤0.03 ≤0.02 0~+2 ≤1.5 ≤1.0
0.27 ±0.03
0.30
0.35

Notes:
a. Delivery of untrimmed products is allowable, with a permissible width deviation ranging from 0 to +5mm.
b. The allowable thickness difference refers to the thickness difference between the middle of the steel sheet and the part that is 15mm away from the edge.
c. The longitudinal thickness difference refers to the difference between the maximum thickness value and the minimum thickness value that are measured in the lengthwise direction (parallel to the rolling direction of any steel strip that is 2 meters long.
d. As for users with special requirements, Baosteel can deliver products according to the standard +α.

 

 